SUPER KNOWLEDGE 313
#FireAlarmSystem & #फायरअलार्मसिस्टम #firefightingsystem , #safety , ,#electronics, #technical #bms #techyoutuber
Welcome to Super Knowledge 313 – your trusted source for Fire Alarm Systems, Fire Fighting and Low Current Systems.
I am a Fire Alarm Engineer with a three-year Diploma in Engineering, sharing my real-world experience from the field. On this channel, you’ll find both theory and practical tutorials that help engineers, technicians, and students build strong knowledge in Fire Alarm and safety systems.
🔥 What I Cover:
Fire Alarm System Programming & Troubleshooting
Fire Fighting & Fire Safety Systems
Low Current Systems & BMS
Practical On-Site Demonstrations + Theory Explanations
👨🔧 Who This Channel Is For:
Fire Alarm Engineers & Technicians
Electrical & Electronics Diploma / Degree Students
Professionals
🌍 Why Subscribe?
Practical videos from real projects
Step-by-step tutorials in English, Hindi, and Urdu/Arabic terms for global understanding
Как указать адрес в детекторе дыма Detnov || #DetnovFireAlarm #firealarmcommissioning #address
How to connect Honeywell Farenhyte panel to PC || HFSS TUTORIAL | #farenhyte #HFSS #honeywell #TRIGA
NFS2-3030 NOTIFIER PROGRAMMING || VERIFIRE TOOL || LOGIC EQUATION #notifier #verifier #programming
Verifier Tool Logic Equation || NFS2-3030 XP6 RELAY Programming ||NETWORK Programming #Verifiertool
DOWNLOAD AND UPLOAD DATA FROM BOSCH PANEL || AVENAR 8000 PANEL| BOSCH PANEL||BOSCH PANEL PROGRAMMING
How to check the Software Version of Simplex panels| 4100ES PANEL SOFTWARE |ES PROGRAMMER | #simplex
NOTIFIER PANEL PROGRAMMING|Fire Alarm Panel Programming #firealarm #notifier #programming #verifier
GENT PANEL PROGRAMMING || FIRE ALARM PANEL PROGRAMMING BY SOFTWARE #gent #programming #software
ОБЫЧНАЯ ПАНЕЛЬ XENEX GENT | Пароль панели Xenex | Отключить и включить на панели Xenex #gent #xenex
Устранение неисправностей Smart Connect Multiloop | Ошибка разрыва шлейфа | Конфигурация шлейфа #...
Zeta Premier AL fire Alarm panel Password || Premier Al Panel Software |#zeta #firealarm #premierAL
УВЕДОМЛИТЕЛЬ NFS2-3030 || NFS2-3030 РУКОВОДСТВО ПО ПРОГРАММИРОВАНИЮ || #уведомитель #honeywell #п...
GENT PANEL NETWORK CARD NODE ADDRESS SETTING || NETWORK SETTING IN GENT PANEL || #gent #firealarm
DETECTOMAT DC3500 PANEL PROGRAMMING || DETECTOMAT FIRE ALARM PANEL PROGRAMING #DC3500M #DETECTOMAT
EATON COOPER FX6000 FIRE ALARM PANEL || #cooper #eaton #CF3000 | #cf3000cooper fire panel || #FX6000
GENT VIGILON PANEL ME FAULT , DISABLE AUR WARN KAISE CHECK KAREN ||#gent #firealarm #troubleshooting
Как проверить/вывести ошибку, отключить и предупредить на панели Gent Vigilon || #firealarm #gent...
HOW TO SOLVE CORRUPTED CONFIG MEMORY AT CARD 14 FAULT IN GENT #firealarm INVALIDCONFIGURATION #gent
GENT VIGILON PANEL PROGRAMMING || HOW TO PUT DELAY IN GENT PANEL || #gent #programming #firealarm
FIRE ALARM REPEATER PANEL |SMART CONNECT REPEATER PANEL |HOW TO RESET MCP #MCP #zeta #repeaterpanel
INFINITY 8 PANEL CONNECTION || ZT-CP4 MCP CONNECTION || ZRPB/R SOUNDER CONNECTION | #zeta #infinity8
HOW TO ADD/REMOVE A DEVICE IN SMART CONNECT MULITILOOP PANEL || #firealarm #firealarmsystem #zeta
ПРОГРАММИРОВАНИЕ МНОГОШЛЮЗОВОЙ ПАНЕЛИ ZETA SMART CONNECT || ZETA SMART CONNECT||#zeta #firealarm ...
How to add a new device in ZETA SMARTCONNECT MULTILOOP PANEL ||LOOP CONFIGURATION #zeta #فاير #फायर
SIMPLEX 4100ES FIRE ALARM PANEL TROUBLESHOOTING | SIMPLEX4007ES TROUBLESHOOTING #simplex #firealarm
Zeta Smoke Detector Base and LED Connection ||Zeta Addressable & Conventional Detector wiring #zeta
Zeta Smart Connect Multi loop Panel || zeta smart connect || #zeta #firealarm @superknowledge3135
GENT VIGILON PANEL TROUBLESHOOTING || #gent #gentbyhoneywell #firealarm @superknowledge3135 #how
Open Fault Troubleshooting in fire alarm panel || Short fault in fire alarm panel ||#zeta #firealarm
GENT VIGILON TROUBLESHOOTING || Honeywell gent panel || #gent #फायर #firealarm || ASCII FAULT ||