Electrical Concept
Electrical Engineer
How to Review Materials Technical Submittal | Step-by-Step Guide.
How to Correctly Position Fire Alarm Sounders & Visual Alarms | Fire Alarm System Designing – Part 7
How to correctly position the smoke and heat detector in the fire alarm system designing-Part-6
How to correctly position Manual Call Points (MCP) in Fire Alarm System designing-Part-5
Alarm zoning for fire alarm system -Part-4 | Fire alarm system designing #firealarmdesign
How to select Fire Alarm detection zone -Part-3 | Fire Alarm System Designing #firealarmdesign
How to select different fire alarm protection levels--Part-2 | Fire Alarm System Designing
Different level of fire alarm protection-M, L1,L2,L3,L4 and L5 - Part-1| Fire Alarm system Designing
Protection Angel Method for Lightning protection system Designing-Part-6 | #lightningprotection
Mesh Method for Lightning protection system-Part-5 | #lightningprotection
Rolling Sphere Method for LPS system designing -Part-4 | Designing of #lightningprotection system
Different Method for designing of lightning protection system-Part-3 #lightningprotection #lightning
Class of Lightning protection system-Part-2 | Designing of #lightning protection system
Risk Assessment for Lightning protection system- Part-1 | Designing of #lightningprotection system
DEWA Regulation key points -Part-2 | #dewa #dewa19
DEWA Regulation key points-Part-1 | #dewa19
Introduction of Demand factor-Part-11 | G+4 building designing as per DEWA Regulation. #dewa
ELCB sensitive rating for different type of load as per DEWA Regulation
MDB designing as per DEWA Regulation- Part-10 | Designing of G+4 building as per #dewa Regulation
MDB designing as per DEWA regulation-Part-9 | Designing of G+4 building as per DEWA Regulation.
Type of Power Cables based on its construction
ADDC Regulation Related to Distribution Board.
Difference between DEWA and ADDC regulation-Part-1
ФОРМА конструкции электрического щита - Часть 4 | Что такое Тип 1, 2, 3, 4, 5, 6 и 7
FORM of Construction for Electrical panel-Part-3 | what is Type-1,2,3,4,5,6 & 7| what a & b denotes
Why OLR is needed in a Motor Circuit Despite MCCB also capable to give protection against over load.
ФОРМА КОНСТРУКЦИИ ДЛЯ ЭЛЕКТРОЩИТА-ЧАСТЬ-2 | Что такое формы-1,2,3 и 4 для электрощита?
ФОРМА КОНСТРУКЦИИ ДЛЯ ЭЛЕКТРОЩИТОВ - Часть 1 | Что такое Форма 1, 2, 3 и 4 для электрощитов?
MDB Designing as per DEWA Regulations | Designing of G+4 building as per DEWA -Part-8 #dewa
Disadvantage of Poor Power Factor. | Capacitor bank sizing - Part-4