Recovery of Refrigerant On A Window Unit
Автор: Electrical and HVACR Training Center
Загружено: 2020-03-27
Просмотров: 15953
HVAC Level 1 Instructor Mr. Massaro
1. Zero Manifold Gauge Set
2. Hook blue hose to low side of system, red hose to high side of system.
3. Hook yellow hose to the on recovery machine in thermal, hook a 4th hose to the out on a recovery machine to the recovery tank.
4. Bleed air out of line through the recover machine to recovery tank.
5. Zero out scale open manifold low & high sides open vapor side of tank and turn recovery machine on and open valve on hose to tank and recovery the refrigerant.