Surge l Surge In centrifugal Compressor l
Автор: Girish Shinde
Загружено: 2023-02-28
Просмотров: 13743
Class Notes
In a centrifugal compressor, surge refers to a phenomenon where the compressor experiences a reversal of flow due to a sudden decrease in the pressure ratio across the compressor. Surge is characterized by the compressor experiencing a momentary flow reversal, causing a sudden increase in pressure, temperature, and vibration levels within the compressor.
There can be several reasons for a surge in a centrifugal compressor, which occurs when the compressor experiences a reversal of flow and a decrease in pressure. Some of the common causes of surge in a centrifugal compressor are:
Rapid changes in load: A sudden increase or decrease in the demand for compressed air can cause the compressor to surge. This can happen, for example, if a large air-operated device is turned on or off quickly.
Inlet blockage: Any obstruction in the compressor's inlet, such as a clogged air filter or a malfunctioning inlet valve, can cause the compressor to surge.
High discharge pressure: If the compressor's discharge pressure is too high, it can cause a surge. This can happen, for example, if the compressor is trying to compress air that is already at a high pressure.
Low flow rate: If the flow rate of air through the compressor is too low, it can cause a surge. This can happen, for example, if the compressor is oversized for the application or if the inlet or discharge piping is too small.
Compressor damage: Any damage to the compressor, such as worn impellers or bearings, can cause a surge.
It's important to prevent surging in a centrifugal compressor as it can cause damage to the compressor and other equipment, as well as increase energy consumption and decrease efficiency.
Surge can have several negative effects on a centrifugal compressor, including:
Reduced efficiency: Surge can cause the compressor to operate inefficiently, which can result in higher energy consumption and increased operating costs.
Vibration and mechanical stress: Surge can cause rapid and severe pressure and flow fluctuations within the compressor, which can lead to high levels of vibration and mechanical stress. This can cause damage to the compressor's components, such as the impeller, diffuser, or bearings, and can reduce the compressor's lifespan.
Noise: Surge can cause significant noise levels within the compressor, which can be disruptive and potentially hazardous for personnel working nearby.
Heat generation: Surge can cause rapid changes in gas flow and temperature within the compressor, which can lead to the generation of excess heat. This can cause damage to the compressor's components and lead to premature failure.
Unstable process conditions: Surge can lead to unstable process conditions downstream of the compressor, which can have negative effects on downstream equipment and processes.
Safety risks: In extreme cases, surge can cause catastrophic failure of the compressor, which can pose significant safety risks to personnel and equipment in the vicinity.
A surge control system is an essential component of a centrifugal compressor that is designed to prevent the compressor from surging. The surge control system is typically composed of sensors, controllers, and actuation devices that work together to detect and prevent surge conditions.
The basic operation of a surge control system involves monitoring the compressor's operating conditions, such as flow rate, pressure, and temperature, and comparing these values to a predetermined safe operating range. If the compressor's operating conditions approach the surge limit, the surge control system takes corrective action to prevent surge.
The corrective action taken by the surge control system may involve adjusting the compressor's inlet guide vanes, which control the amount of gas flow into the compressor. The surge control system may also actuate a recycle valve, which diverts a portion of the compressed gas back to the compressor's inlet, reducing the compressor's flow rate and preventing surge.
00:00 What is Surge ?
8:29 Reasons for Surge
10:11 Effect of Surge on Compressor
11:57 Surge Control System
For Course Details, WhatsApp 9082044810
कोर्स की जानकारी के लिए WhatsApp 9082044810
Available Course / उपलब्ध पाठ्यक्रम
https://drive.google.com/drive/folder...
E Mail :- [email protected]
/ girishshindehvac
/ girish_shinde_academy
https://www.amazon.in/shop/girishshinde
#girishshinde #airconditioning #hvac
Доступные форматы для скачивания:
Скачать видео mp4
-
Информация по загрузке: