Change motor capacitor in an Elite Liftmaster CSW200 swing gate operator
Автор: Jacob Gilliam Master Tech
Загружено: 2021-05-02
Просмотров: 6172
Repairing a swing gate operator. Here's how to replace the start capacitor on an Elite Liftmaster CSW200 swing gate operator with a Q400 control board and a Q018 motor, with Jacob Gilliam Master Tech.
Turn the power off to the gate opener and replace with new OEM factory part.
Liftmaster part number:
K29C-65AU2415 (old Elite part number Q027)
Things used in this video:
1) common sense
2) flathead screwdriver
3) a set of wire strippers with plier tips
Thermal Expansion:
"Thermal expansion is the tendency of matter to change its shape, area, volume, and density in response to a change in temperature, usually not including phase transitions."
https://en.wikipedia.org/wiki/Thermal...
As gate operators age, connections that are not soldered experience temperature changes throughout their life and can slowly change from their orginal shape. In this case, the female wire connectors every so slightly enlarge or spread apart and the connections with the male terminals become looser.
Gate operator installations, advise, tips, guidance, consulting, DIY repairs, and general vehicular gate and gate opener knowledge with Jacob Gilliam, a Certified Electronics Technologist and master level gate technician with 17+ years of daily experience. Jacob is all about #noexcuses gate automation.
www.jacobgilliam.com
#automaticgatesbyjacob #jacobgilliam #jacobgilliammastertech #mastergatetech #noexcusesgateautomation #noexcuses