Mach3 Edge finder buttons
Автор: Jim Taylor
Загружено: 2017-03-06
Просмотров: 38096
This completes the programming of the edge-finder buttons in Mach3. Below is the VBscript for the buttons. Simply copy (highlight then Ctrl-C) the relevant section for each button and then paste it into the VBscript editor.
NOTE: replace NE with the two not-equals angle brackets
Rem VBScript To probe bottom edge
If GetOemLed (825) NE 0 Then 'Check to see if the probe is already grounded or faulty
Code "(Probe plate is grounded, check connection and try again)"
Else
FeedCurrent = GetOemDRO(818) 'Get the current settings
XCurrent = GetDro(0)
Current = GetDro(1)
Code "G4 P1" 'Pause 1 second to give time to position probe plate
Code "F100" 'slow feed rate to 100 mmpm
Rem Probe up
YNew = YCurrent + 75
Code "G31 Y" &YNew
While IsMoving()
Wend
YPos1 = GetVar(2001)
Code "G0 Y" &YCurrent
Code "F" &FeedCurrent 'restore starting feed rate
Call SetDro (1,Abs(getoemdro(1000))/(-2))
End If
Rem End of To probe bottom edge script.
Rem VBScript To probe LH edge
If GetOemLed (825) NE 0 Then 'Check to see if the probe is already grounded or faulty
Code "(Probe plate is grounded, check connection and try again)"
Else
FeedCurrent = GetOemDRO(818) 'Get the current settings
XCurrent = GetDro(0)
YCurrent = GetDro(1)
Code "G4 P1" 'Pause 1 second to give time to position probe plate
Code "F100" 'slow feed rate to 100 mmpm
Rem Probe Right
XNew = XCurrent + 75 'probe 75 mm to right
Code "G31 X" &XNew
While IsMoving()
Wend
Code "F" &FeedCurrent 'restore starting feed rate
Call SetDro (0,Abs(getoemdro(1000))/(-2))
End If
Rem End of To probe LH edge VBscript
Rem VBScript To probe RH edge
If GetOemLed (825) NE 0 Then 'Check to see if the probe is already grounded or faulty
Code "(Probe plate is grounded, check connection and try again)"
Else
FeedCurrent = GetOemDRO(818) 'Get the current settings
XCurrent = GetDro(0)
YCurrent = GetDro(1)
Code "G4 P1" 'Pause 1 second to give time to position probe plate
Code "F100" 'slow feed rate to 100 mmpm
Rem Probe Right
XNew = XCurrent - 75 'probe 75 mm to left
Code "G31 X" &XNew
While IsMoving()
Wend
Code "F" &FeedCurrent 'restore starting feed rate
Call SetDro (0,Abs(getoemdro(1000))/(+2))
End If
Rem End of To probe RH edge VBscript
Rem VBScript To probe top edge
If GetOemLed (825) NE 0 Then 'Check to see if the probe is already grounded or faulty
Code "(Probe plate is grounded, check connection and try again)"
Else
FeedCurrent = GetOemDRO(818) 'Get the current settings
XCurrent = GetDro(0)
Current = GetDro(1)
Code "G4 P1" 'Pause 1 second to give time to position probe plate
Code "F100" 'slow feed rate to 100 mmpm
Rem Probe up
YNew = YCurrent - 75
Code "G31 Y" &YNew
While IsMoving()
Wend
YPos1 = GetVar(2001)
Code "G0 Y" &YCurrent
Code "F" &FeedCurrent 'restore starting feed rate
Call SetDro (1,Abs(getoemdro(1000))/(+2))
End If
Rem End of To probe top edge VBscript
Доступные форматы для скачивания:
Скачать видео mp4
-
Информация по загрузке: