Dangers using Auto Transformers and 230V Inverters in North America
Автор: Watts247 Channel
Загружено: 2022-01-14
Просмотров: 36290
While its becoming popular to Throw an Auto Transformer at a 230V inverter for creating split phase, there are many unseen precautions that must be taken and observed in doing so. Simply following solutions and hacks blindly can be both dangerous and Costly
00:00 Introduction to this "popular" "solution"
01:11 Issue # 1
02:18 The Science between Isolated & Non Isolated
04:10 Inside the 230V European / International Inverter
06:15 A non solution to a problem - Grounding the Inverter, floating at 120V
06:48 A North American house wiring example, split phase explanation
12:47 Differences between an Auto and Isolation Transformer
13:12 Opening and modifying (removing bonding screw)
16:20 Opening and Modifying the PIP 8048Max
20:55 Issue #2
21:25 Transformer Sizing
22:35 In Conclusion
Доступные форматы для скачивания:
Скачать видео mp4
-
Информация по загрузке: