The LC8 input module allows RMC200 users to bring up to eight load cell signals straight into to the motion controller - no signal conditioner or amplifier needed. In this presentation, Delta's Product Development Manager Jacob Paso gives a brief introduction to the basic theory of load cell operation, and how the LC8 module provides excitation voltage, sense wire correction, and much more. Live examples include controlling force using load cell feedback, comparing and contrasting load cell vs. differential pressure feedback, and creating a calibration curve using RMCTools' Custom Feedback feature.
00:00 Introduction
03:50 Load Cell and Strain Gauge basic theory
06:10 Wheatstone Bridges
09:52 Output voltage of Wheatstone Bridge load cells
14:43 Wire Compensation
16:55 LC8 wiring
18:56 Configuring the LC8 in RMCTools
27:41 LC8 use example with live system
33:28 Load Cell vs. Differential Pressure Sensor feedback - example
46:29 Advanced topics: Multi-point calibration, wiring strain gauges, external excitation voltage, minimum input filter frequency