This video offers a comprehensive walkthrough for setting up and adjusting the gas pilot flame on a Nayati NGKB commercial kitchen unit. We guide you through every essential step, from initial checks to final adjustments.
Required Tools:
Multimeter (for voltage and resistance checks)
Flathead Screwdriver
What this video covers:
Initial Checks: Power on and verify the pressure switch (correct hose connection, pressure setting at 500Pa or below, and checking continuity with an ohmmeter).
Pilot Preparation: Opening the pilot gas valve and closing the air adjuster.
Setting Gas Flow: Correctly rotating the pilot flame adjuster for initial setup.
Ignition: How to ignite the pilot flame (using gas and flame triggers).
Flame Adjustment: Gradually opening the air pilot adjuster to achieve a stable, blue flame.
Thermocouple Measurement: A voltmeter measures the TC interrupter output while the pilot is active, and the pilot flame adjuster is adjusted to ensure the voltage is above 1.7V for reliable operation.
Stabilization: Ensuring the pilot flame remains stable after setup.
Watch carefully and follow these instructions to configure your Nayati NGKB's pilot system correctly.
Safety Notice: Working with gas appliances requires proper knowledge and safety procedures. If you are unsure, consult a qualified professional or contact our aftersales team.