🔥JUAL BURNER RIELLO PRESS 3G MADE IN ITALY☎️✔081388666204🔥
Автор: RATMAN WONOSOBO - PT INDIRA MITRA BOILER
Загружено: 2020-07-15
Просмотров: 3900
• 🔥JUAL BURNER RIELLO PRESS 3G MADE IN ITALY... Sales ☎️✔081388666204🔥
🔥OIL BURNER RIELLO PRESS 3G🔥 MADE IN ITALY🔥
LIGHT OIL (TWO STAGE)
PRESS 3G
TWO STAGE LIGHT OIL BURNERS
PRESS G SERIES
PRESS GW 107/178 ÷ 356 kW
PRESS 1G 130/190 ÷ 534 kW
PRESS 2G 214/356 ÷ 712 kW
PRESS 3G 273/534 ÷ 1168 kW
PRESS 4G 415/830 ÷ 1660 kW
The PRESS G series of burners covers a firing range from 107 to 1660 kW and they have been designed for use in civil installations of average dimensions, like building areas and large apartment groups or for use in industrial applications, like small or medium plants. Operation is two stage; the burners are fitted with a microprocessor-based burner safety control box which supplies indication of operation and diagnosis of fault cause. The combustion head, that can be set on the basis of required output, allows optimal performance ensuring good combustion and reducing fuel consumption.
The main feature of these burners is their reliability due to a simple and strong construction, that permits operation without particular maintenance intervention. Simplified maintenance is achieved by the slide bar system, which allows easy access to all of the essential components of the combustion head. All electrical components are easily accessible only by dismounting a protection panel, thus guaranteeing a quick and simple intervention on components.
The burners are fitted with two oil delivery valves.
A control device, on the basis of required output, regulates
oil delivery valves opening, allowing light oil passage
trough the valves and the nozzles.
2nd stage delivery valve opening supplies the hydraulic
ram which open the air damper in relation to the fuel
burnt on 2nd stage.
All burners are fitted with a self-priming pump with filter
and pressure regulator
The ventilation circuit of PRESS burners is inserted in a extremely
compact structure and it is provided
with a forward blades centrifugal fan,
which guarantees high pressure levels
at the required air deliveries and permits installation
flexibility.
Delivery oil valves opening supplies the adjustable
hydraulic ram which regulates air delivery in relation
to the fuel burnt on 2nd stage
For the PRESS G series of burners a special kit for increasing
combustion head length is available.
The choice of using it depends on the
thickness of the front panel and the type of boiler.
Depending on the type of generator, check that the
penetration of the head into the combustion chamber
is correct.
The internal position of the combustion head can easily
be adjusted to the maximum defined output by adjusting
a screw.
Example of a PRESS G burner
combustion head
Example of air damper indexed selector
and hydraulic ram of PRESS G burners
Dimensions of the flam
Burner:
Monoblock forced draught oil burner with two stage operation, fully automatic, made up of:
Air suction circuit lined with sound-proofing material
Fan with forward curve blades with high performance concerning pressure and air delivery
Air damper for air setting
Hydraulic ram for air damper control
Starting motor at 2800 rpm, three-phase 400V with neutral, 50Hz (single-phase, 230V and 50Hz for
the PRESS GW model)
Combustion head, that can be set on the basis of required output, fitted with:
stainless steel end cone, resistant to corrosion and high temperatures
ignition electrodes
flame stability disk
Fan pressure test point
Gears pump for high pressure fuel supply, fitted with:
filter
pressure regulator
connections for installing a pressure gauge and vacuometer
internal by-pass for single pipe installation
Valve unit with two delivery oil valves on the output circuit
Photocell for flame detection
Microprocessor-based flame control panel, with diagnostic function
Slide bars for easier installation and maintenance
Protection filter against radio interference
IP 44 electric protection level.
Conforming to:
89/336/EEC directive (electromagnetic compatibility)
73/23/EEC directive (low voltage)
92/42/EEC directive (performance)
98/37/EEC directive (machinery)
EN 267 (liquid fuel burners).
Standard equipment:
2 flexible pipes for connection to the oil supply network
2 gaskets for the flexible pipes
2 nipples for connection to the pump
4 screws for fixing the burner flange to the boiler
1 thermal screen
Instruction handbook for installation, use and maintenance
Spare parts catalogue.
Available accessories to be ordered separately:
Nozzles
Head extension kit
Head length reduction kit
Sound-proofing box
Degasing unit (with or without filter)
Air damper complete closure kit
PC interface kit
#RIELLOPRESS3G #OILBURNERRIELLO #OILBURNERRIELLOPRESS3G
https://indira.co.id
Ratman Bejo
☎️✔081388666204🔥
https://www.youtube.com/feed/my_videos
https://www.facebook.com/ratman.bejo?...
/ idm_boiler
/ ratmanbejo
/ ratman_0505
/ boiler1
Доступные форматы для скачивания:
Скачать видео mp4
-
Информация по загрузке: