Steam heating cycles with springless Pressuretrol
Автор: NJ Steam Help
Загружено: 2018-11-17
Просмотров: 7660
I couldn’t get my Pressuretrol to cut out early enough until I took the spring off! This video shows cycles to take my house from 70f to 72f
Questions: Is this short-cycling? Or just normal behavior recovering from a 2° setback? Why is 1.5 psi the magic cutout number? Why not 1.75 or 1.25? Can I "under-fire" my boiler to make it cycle less? Why did the pressure drop during the initial firing cycle???
Index:
Start of video, just after boiler started to produce steam: • Steam heating cycles with springless Press...
Steam pressure starts to rise, 3:30: • Steam heating cycles with springless Press...
0.5 psi, 12:45: • Steam heating cycles with springless Press...
0.80 psi, 15:48 Pressure starts to drop! Why!? • Steam heating cycles with springless Press...
0.10 psi 17:57, bottom of weird pressure drop! • Steam heating cycles with springless Press...
22:08 Springless pressuretrol cuts out at ~1.40psi!! • Steam heating cycles with springless Press...
23:12 Springless Pressuretrol cuts in for cycle 2 at 0.4 psi: • Steam heating cycles with springless Press...
26:11 Cycle 2 cuts out at 1.4psi: • Steam heating cycles with springless Press...
27:17 Cycle 3 cuts in at 0.35 psi: • Steam heating cycles with springless Press...
30:59 Cycle 3 cuts out at 1.70 psi after I bump the differential up: • Steam heating cycles with springless Press...
32:22 Cycle 4 cuts in at 0.4 psi: • Steam heating cycles with springless Press...
35:29 Cycle 4 cuts out at 1.6 psi after differential adjustment: • Steam heating cycles with springless Press...
36:42 Cycle 5 cuts in at 36:42: • Steam heating cycles with springless Press...
39:37 Cycle 5 cuts out at 1.6 psi: • Steam heating cycles with springless Press...
40:54 Cycle 6 cuts in at 0.4 psi: • Steam heating cycles with springless Press...
43:47 Cycle 6 cuts out at 1.6 psi: • Steam heating cycles with springless Press...
45:04 Cycle 7 cuts in at 0.4 psi: • Steam heating cycles with springless Press...
47:53 Cycle 7 cuts out at 1.6 psi: • Steam heating cycles with springless Press...
49:08 Cycle 8 cuts in at 0.4 psi: • Steam heating cycles with springless Press...
51:36 Cycle 8 cuts out at the magical 1.5 psi after differential adjustment: • Steam heating cycles with springless Press...
52:46 Cycle 9 cuts in at 0.4 psi: • Steam heating cycles with springless Press...
55:14 Cycle 9 cuts out at 1.5 psi: • Steam heating cycles with springless Press...
56:23 Cycle 10 cuts in at 0.4 psi: • Steam heating cycles with springless Press...
57:12 Cycle 10 ends with thermostat satisfied at 0.75 psi: • Steam heating cycles with springless Press...
Доступные форматы для скачивания:
Скачать видео mp4
-
Информация по загрузке: