Yaskawa General Purpose Inverter Drive CIMR-J1000 Static Check
Автор: Precision Zone, Inc.
Загружено: 2016-12-01
Просмотров: 14766
Precision Zone – Static Check for Yaskawa CIMR-J1000 Inverter in Chicago & Wheeling
At Precision Zone, located in Wheeling near Chicago, we specialize in diagnostics, troubleshooting, and repair for Yaskawa CIMR-J1000 series inverters. In this video, Rob demonstrates how to perform a static check on the J1000 series inverter to ensure proper operation and detect potential failures.
Step-by-Step Static Check for Yaskawa CIMR-J1000 Inverter:
✔ Step 1: Power Down & Discharge the DC Bus
Turn off the drive and disconnect all incoming power and motor output lines.
Verify DC bus discharge:
Check the charge lamp (should be off).
Even if the lamp is off, double-check voltage using a multimeter before proceeding.
✔ Step 2: Perform a Phase-to-Ground Test
Set your multimeter to resistance mode.
Locate a proper ground point for accurate measurements.
Measure each input phase (R, S, T) and output phase (U, V, W) to ground.
None of the inputs or outputs should be shorted to ground.
✔ Step 3: Test Input & Output Transistor Modules
Set your multimeter to diode mode.
Place the negative probe on the positive DC bus terminal, then measure:
Input terminals (R, S, T) with the positive probe.
Voltage should be between 0.2 – 1V.
Readings should be balanced across all three phases.
Switch the probe leads:
Positive probe to the negative bus terminal.
Repeat measurements for R, S, T and U, V, W.
Verify output readings (U, V, W) with both probe positions.
Ensure all readings remain within the expected range.
💡 If you detect inconsistencies, further troubleshooting or professional repair may be required.
Precision Zone Services in Chicago & Wheeling:
✅ Yaskawa CIMR-J1000 drive repair & diagnostics
✅ Servo motor troubleshooting & industrial automation solutions
✅ Power supply and encoder repair services
✅ Comprehensive drive testing & component-level repair
📞 For expert repair guidance or more information, call Precision Zone at (800)-551-4420 or visit www.PrecisionZone.net.
#YaskawaJ1000 #CIMRJ1000 #DriveRepair #StaticCheck #IndustrialAutomation #MotorControl #PrecisionZone #Chicago #Wheeling
Доступные форматы для скачивания:
Скачать видео mp4
-
Информация по загрузке: